Influence of the channel design on the heat and mass exchange of induction channel furnace
2011
PurposeThe purpose of this paper is to present in‐depth numerical modelling of heat and mass exchange in industrial induction channel furnace (ICF).Design/methodology/approachThe turbulent heat and mass exchange in the melt is calculated using a three‐dimensional (3D) electromagnetic model and a 3D transient large eddy simulation method. The simulation model has been verified by flow velocity and temperature measurements, which were carried out using an industrial sized channel inductor operating with Wood's metal as a low temperature model melt.FindingsThe ICF is well‐established for melting, holding and casting in the metallurgical industry. But there are still open questions regarding th…
Acute inactivation of the medial forebrain bundle imposes oscillations in the SNr: a challenge for the 6-OHDA model?
2010
It has been recently shown that the substantia nigra pars reticulata (SNr) of 6-hydroxydopamine (6-OHDA)-lesioned rats, under urethane anaesthesia, manifests a prominent low frequency oscillation (LFO) of around 1Hz, synchronized with cortical slow wave activity (SWA). Nevertheless, it is poorly understood whether these electrophysiological alterations are correlated only with severe dopamine depletion or may also play a relevant pathogenetic role in the early stages of the dopamine denervation. Hence, here we recorded SNr single units and electrocorticogram (ECoG) in two models of dopamine denervation: (i) acute dopamine denervated rats, obtained by injection of tetrodotoxin (TTX), (ii) ch…